Alloy choice, corrosion allowance and coating system are not independent. The alloy’s PREN sets the minimum chloride resistance, the coating adds barrier protection, and the combination of the two determines the life at the given exposure.
The Exposure Zones
Note that splash and submerged are not identical in mechanism. Splash is faster corrosion than submerged because of the oxygen access and the wet-dry cycle, which removes corrosion products and exposes fresh metal. This matters for coating and alloy choices.
Component Categories and Their Alloy Needs
The split between “heavy coated carbon steel” and “duplex stainless” in this table is an economic one. A duplex stainless component has a much higher material cost, but it avoids the galvanic coupling that occurs when a less noble metal is bolted to a stainless or bronze component, and it tolerates coating damage better.
PREN: What It Says and What It Does Not
The pitting resistance equivalent number is still the single most useful starting point for a marine alloy selection, but it should be understood as a screening tool rather than a definitive answer.
PREN = Cr + 3.3 × Mo + 16 × N
Two important caveats. PREN says nothing about crevice corrosion resistance, which is more demanding than pitting, and nothing about galvanic coupling when the casting is bolted to a different metal. Both are common marine failure modes that a PREN selection misses.
Galvanic Coupling: The Overlooked Variable
A carbon steel bracket bolted to a duplex pump body in seawater is not one problem, it is two. The steel corrodes faster than it would alone, because it becomes the anode in a galvanic cell, and the duplex is protected by the current from that corrosion, which can mask an actual design problem until the steel is gone.
Galvanic compatibility matters for every junction: bracket to body, bolt to casting, pipe flange to casting, sacrificial anode to structure. The remedy is either to use compatible metals, to isolate the two with an insulating gasket or sleeve, or to design the arrangement so the area ratio and conductivity favour the more reactive metal rather than the more noble one.
Coating System Selection by Exposure
Surface preparation is the single most important part of any coating system. SSPC-SP10 (near-white metal blast) with a specified profile is the standard starting point for marine carbon steel coatings, and cutting corners on preparation is the single largest cause of premature coating failure in offshore structures.
Passivation matters on cast stainless and duplex stainless too, because casting leaves residual free iron on the surface. The correct passivation process removes that free iron and re-establishes the chromium oxide passive layer, and it should be specified explicitly rather than left to the foundry’s standard practice.
Corrosion Allowance
Where a coating or the alloy itself provides limited protection, a corrosion allowance must be added on top of the structural requirement. The allowance is sized from the expected corrosion rate, the design life and whether the corrosion is uniform or localised.
The last row is important. A duplex coated carbon steel component is not equivalent to a solid duplex component. If the coating is scratched, the steel beneath becomes the anode and corrodes rapidly under the scratch, producing a localised defect rather than general thinning. The allowance for this mode must allow for localised penetration rather than uniform loss.
Crevices and Design Details That Fail First
- Bolted joints and gasketed flanges, where the gap between two metals in seawater becomes a crevice.
- Welded fillets and undercuts, which trap moisture and accelerate local attack.
- Sediment traps and low points in submerged pipework, where sediment settles and creates an anaerobic environment.
- Thread roots in threaded joints, which are both crevices and stress concentrations.
- Sacrificial anodes that are undersized or made from the wrong alloy, so they corrode themselves too quickly.
- Parts that span exposure zones, where one end is in atmospheric and the other in submerged service.
Inspection and Verification
- Chemical analysis of the cast alloy, confirming composition against the PREN or grade specification.
- Positive material identification on delivered parts, particularly to distinguish visually similar austenitic and duplex grades.
- Passivation verification on cast stainless and duplex parts, including test for free iron.
- Surface preparation documentation before coating, including blast profile and cleanliness standard.
- Coating thickness measurement on every coated surface, because the specified thickness is the main line of protection.
- Radiography or penetrant testing on pressure-retaining or load-bearing sections, where internal porosity would be a structural concern.
- Dimensional inspection of bolted interfaces, flanges and passages, where misfit creates crevices.
- Galvanic compatibility review of the whole assembly, not just the casting in isolation.
Common Mistakes
- Selecting an alloy by PREN alone and overlooking crevice corrosion resistance.
- Using the same coating system for splash and submerged zones.
- Specifying austenitic 316 in stagnant seawater and being surprised by crevice attack.
- Forgetting galvanic coupling between casting and adjoining components.
- Counting on a coating without specifying surface preparation.
- Treating corrosion allowance as a substitute for correct alloy selection.
- Passivating cast stainless and then welding on a bracket without re-passivating.
- Ignoring MIC risk on deep subsea and buried components.
- Accepting a duplex coated carbon steel as equivalent to a solid duplex without coating damage allowance.
- Assuming marine salt spray is the same environment as splash zone exposure.
About ATM-Casting
ATM-Casting produces cast components for marine and offshore environments in carbon and low-alloy steels, stainless and duplex stainless, nickel alloys and wear-resistant bronzes, supported by alloy selection review against PREN, exposure zone and galvanic compatibility requirements. Coating systems are matched to the zone, with surface preparation specified alongside thickness targets, and passivation for stainless and duplex components is carried out and verified. Inspection includes lot-matched chemical analysis, positive material identification on delivered parts, penetrant and radiographic testing on load-bearing sections, and full traceability by heat and lot. Sacrificial anode and galvanic protection schemes can be reviewed as part of the casting design.